H1 - the revolutionary UV-handlamp-series for all industrial applications

H1: the revolutionary UV-LED-handlamp

maximal security – no flash blinding eyes

H1 is the multifunctional, high-quality and robust UV-light-series for all industrial UV-applications.

The professional lighting system is fully developed in Germany and manufactured at SECU-CHEK.

The wide range of UV-LED-handlamps enables optimal lighting for your specific application.

Do not hesitate to contact us!

 

 

 

Choose the perfect UV-LED-light for your application from 48 models.

 

3 series

 

High-performance UV LED light for demanding industrial applications
With enhanced system monitoring for maximum process security as well
Optimal evaluation and evaluation by means of white light which can be dimmed and superimposed

 

Standard lamp for industrial applications,
Optional with adjustable, reversible white light, with dimming just in time.

 

Simple equipment for standard applications,
Optional with adjustable, reversible white light


3 to 6 UV-high performance-LEDs


2 beam size patterns: area radiation or focussed

 

optional white light functions

Expert advice?

Call +49 6805-942859-0 / Email: info@secu-chek.de

  • Advice from experienced experts
  • Solutions individually tailored to your requirements
  • Price advantage through direct sales
  • Quality Made in Germany
General overview
Series: UVE 365 H1 UVN 365 H1 UVS 365 H1
Typical applications: ALL application areas, preferably demanding time applications with increased demands on process safety in the aviation industry, in engine overhaul and the automotive industry fluorescent, non-destructive magnetic particle testing, penetrant crack detection in industrial use, cleanroom inspections leak detection, curing, drying, NDT-inspections, even in continuous use
Models: H1-09 (3 UV-LEDs) H1-09 (3 UV-LEDs) H1-09 (3 UV-LEDs)
H1-12 (4 UV-LEDs) H1-12 (4 UV-LEDs) H1-12 (4 UV-LEDs)
H1-15 (5 UV-LEDs) H1-15 (5 UV-LEDs) H1-15 (5 UV-LEDs)
H1-18 (6 UV-LEDs) H1-18 (6 UV-LEDs) H1-18 (6 UV-LEDs)
Beam pattern: Flood lamp or
focussed spot
Flood lamp or
focussed spot
Flood lamp or
focussed spot
Optional white light features: Automatically dimmable and superimposed white light,
Whose maximum brightness can be adjusted during operation
Switchable white light, which can be dimmed during operation switchable and pre-adjustable white light output
Specifications and functions of UV-radiation
Series: UVE 365 H1 UVN 365 H1 UVS 365 H1
Wavelength-peak: 365 nm (±5 nm) 365 nm (±5 nm) 365 nm (±5 nm)
Wavelength-Peak securely ensured always during operation
Electronic monitoring of UV-LEDs
Full width half maximum: 18 nm 18 nm 20 nm
Constant operation LEDs (no pulses)
Ripple of the UV radiation: 3 % 3 % 5 %
Numbers of UV-LEDs: 3, 4, 5 or 6* 3, 4, 5 or 6* 3, 4, 5 or 6*
Amount of visible light: 5 Lux ≤ 5 Lux
16 Lux
Integrated UV-passfilter: optional
Typical lifetime T50: ≥ 18.000 hours ≥ 15.000 hours ≥ 12.500 hours
Typical lifetime T70: ≥ 15.000 hours ≥ 12.500 hours ≥ 10.000 hours
Functions for advanced process- and operational safety
Series: UVE 365 H1 UVN 365 H1 UVS 365 H1
Automatic shutdown and reactivation (eco-mode), switchable
Safety switch off at low battery with time delay
Safety switch off at low battery with prewarning
Automatic adaption time signalization (1 minute)
Adjustable adaption time signalization
(1, 3 or 5 minutes)
Custom lamp configuration by user
Exchangeable rubber bumper with integrated protective sheave
UV-intensity and illumination area
Series: UVE 365 H1 UVN 365 H1 UVS 365 H1
UV-A-Intensity in 15 inch (38cm) distance: 1.500 – 15.000 µW/cm² *
(15 – 150 W/m²)*
1.500 – 15.000 µW/cm² *
(15 – 150 W/m²)*
1.200 – 12.000 µW/cm² *
(12 – 120 W/m²)*
Irradiated area
> 1.000 µW / cm² in 15 inch (38 cm):
ø 13 up to 25 cm* ø 13 up to 25 cm* ø 10 up to 21 cm*
Irradiated area
> 100 µW / cm² in 15 inch (38 cm):
ø 25 up to 52 cm* ø 25 up to 52 cm* ø 25 up to 52 cm*
Stability of UV-intensity: ≥ 85 – 95 %* ≥ 85 – 95 %* ≥ 80 – 90 %*
Risk class according to DGZfP EM6: 2*
(for Intensities > 80 W/m²: 3)
2*
(for Intensities > 80 W/m²: 3)
2*
(for Intensities > 80 W/m²: 3)
State signaling
Series: UVE 365 H1 UVN 365 H1 UVS 365 H1
Blue signal-LED for UV-radiation
No irritating yellow or green control-LEDs at UV-operation
Multicolored control-LED
Separate control-LED for UV and white light
Acoustic signal
Tactile vibration signal
Fast, safe and easy status display in the user’s view
Possible qualifications, approvals and fulfilling requirements
Series: UVE 365 H1 UVN 365 H1 UVS 365 H1
Guaranteed requalification possibility for upcoming DIN, EN, ISO and ASTM standards
Qualified ambient temperature range 5 – 50° C 5 – 50° C 5 – 40° C
Detailed certificate and test report ●
DIN EN ISO 3059: 2013-3 (Conditions of observation)
DIN EN ISO 9934: 2013-05 (Magnetic powder test)
DIN EN ISO 3452: 2014 (Penetration test)
ASTM E-2297-04 (2010) (Guide for magnetic powder testing and penetration testing)
ASTM E-3022 (UV-LED-lamps) ●* ●* ●*
ASTM E-1444 M-12 (Magnetic powder test)
ASTM E-1417 M-13 (Penetration test)
Rolls-Royce RRES 90061
(Qualification of UV LED lights)
●* ●* ●*
MTU Aero Engines
Safran Groupe (SNECMA, Turbomeca) no request available no request available no request available
Airbus AITM6-1001 (Penetration test)
Pratt & Whittney SPM (PN 585005) (Penetration test) ●
ASME-Code (BPVS) (Magnetic powder and penetrant testing)
NADCAP (Aviation auditing) no request available no request available no request available
Boeing no request available no request available no request available
General Electric Aviation (GE) no request available no request available no request available
Controls, external control and integration in plants
Series: UVE 365 H1 UVN 365 H1 UVS 365 H1
Integrated touch switch 1 / 5* 1 / 5* 1 / 2*
Comfortable one-hand operation of the white light functions
HOLD function for fixing the white light condition
Connection possibility for external control of the white light, e.g. by foot switch
Connection for external foot dimmer
Control of the luminaire via external machine control (for example PLC of the test bench)
Feedback of the operating state to external control, triggering of external alarms in case of fault or logging by PLC
Direct switching on of the luminaire can be adjusted with voltage supply
Integrated appliances for standard fixtures
Functions and specifications of optional, integrated white light
Series: UVE 365 H1 UVN 365 H1 UVS 365 H1
Preset white light brightness
White light brightness can be changed during operation
Changeover
Between UV radiation and white light
Integration of white light with UV radiation
Automatic adjustment
of white light to UV radiation
Automatic cross-fading
between UV radiation and white light
Variety of white light with relapse option during operation
Uniform, flat, blinding illumination
Illuminance (Lux)
In 38cm distance
up to 5.000 lux* up to 5.000 lux* up to 1.500 lux*
Color temperature 5.300 K – 6.500 K 5.300 K – 6.500 K 5.300 K – 6.500 K
Color rendering index (Ra) ≥ 90 ≥ 90 ≥ 70
Electrical specifications
Series: UVE 365 H1 UVN 365 H1 UVS 365 H1
Type of power supply: External power supply (AC / DC) or
External rechargeable battery (LiIon or NiMH)
External power supply (AC / DC) or
External rechargeable battery (LiIon or NiMH)
External power supply (AC / DC) or
External rechargeable battery (LiIon or NiMH)
Power consumption: 15 W – 50 W* 15 W – 50 W* 15 W – 25 W*
Max. Operating voltage Handset: 50 V DC 50 V DC 50 V DC
Protective low voltage on handset: (≤ 60 VDC) yes yes yes
Protection class: IP 20 with protected electronics IP 20 with protected electronics IP 20 with protected electronics
Protection class: III (Protective low voltage) III (Protective low voltage) III (Protective low voltage)
Technical specifications
Series: UVE 365 H1 UVN 365 H1 UVS 365 H1
Dimensions: 160 x 105 x 95 mm
( 6,3 x 4,1 x 3,7 inch)
160 x 105 x 95 mm
( 6,3 x 4,1 x 3,7 inch)
160 x 105 x 95 mm
( 6,3 x 4,1 x 3,7 inch)
Weight of lamp head: 0,70 kg – 0,85 kg* 0,70 kg – 0,85 kg* 0,70 kg – 0,85 kg*
Active air cooling for maximum service life and safe operation
Electronic monitoring of the fan
Safety shutdown at overtemperature
Extra quiet, temperature controlled fan controller
Operating conditions
Series: UVE 365 H1 UVN 365 H1 UVS 365 H1
Humidity in %: 20- 80 % (not condensing) 20- 80 % (not condensing) 20- 80 % (not condensing)
Permissible ambient temperature: 5 – 50° C 5 – 50° C 5 -40° C

We reserve the right at any time to make technical modifications without announcement.

*: depend on model

We look forward to your inquiry!

You are also welcome to contact us by phone or email.

    Direct contact:

    SECU-CHEK GmbH
    An der Fähre 9
    66271 Kleinblittersdorf
    GERMANY

    Phone +49 6805-942859-0
    Fax +49 6805-942859-95

    Email: info@secu-chek.de

    Google Maps

    By loading the map, you agree to Google's privacy policy.
    Learn more

    Load map