uv-led-lamp.com, An der Faehre 7a-9, 66271 Kleinblittersdorf
Telephone Icon +49 (0)6805-942574-0   Fax Icon +49 (0)6805-942574-7   Email Icon info@uv-led-lamp.com
 
 

UVED-S610-FL Stationary Medium-Size UV-A-LED-Flood-Lamp with System-Monitoring for Maximum Process-Security for non-destructive-testing applications

• fan-control and temperature-monitoring
• overheat-protection to protect the LEDs
• adjustable UV-intensity (in factory)
• integrated operation-hour-meter
• designed for 24/7 operation
• maximum reliability
• high investement protection

stationärer UVED-S610 Flächenstrahler

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

  • UVED S610-FL mit Schutzscheibe
 

UVED-S610-FL Stationary Medium-Size UV-A-LED-Flood-Lamp with System-Monitoring for Maximum Process-Security for non-destructive-testing applications

UVED-S610-FL is a high-end stationay UV-A-LED-Source for maximum contrast and a enhanced irradiated area of 600 x 400 mm. RIL-CHEMIEs high-end systems guarantee maximum investment protection and reliability even if the Sources are used 24/7 in hard industrial condition.

They have an fan-control, temperatur-monitoring and overheat-control. The intensity is programmable in the factory and can be adjusted if necessary.

Further there is an operation-hour-meter integrated to control the intensity over the time of usage. The UVED-Stationary series is Made in Germany and gurarantees maximum performane, quality and life-time for best testing and working ever.


General

Order Number:
800-UVED-S610-FL
 

Special Features

Special Features:
System-Monitoring for Maximum Process-Security
 

Technical Specifications (UV)

Peak-Wavelength:  ?maximum (peak) value of the emitted spectrum
365 (± 5) nm
UV-A Intensity in 38cm Distance:
2.800 µW /cm² (28 W/m²)
Qualified and Approved according to:
ASTM E2297-04 (Reapproved 2010), DGZfP Data Sheet EM6, DIN EN ISO 3059, ASME Boiler and Pressure Vessel Code BPVC Section V
Conform to Standards and Specifications:
AMS 2644, ASTM E165, ASTM E709, ASTM E1208, ASTM E1209, ASTM E1210, ASTM E1219, ASTM E1220, ASTM E1417, ASTM E1418, ASTM E1444
Modifiable UV Intensity (factory-adjustable):
yes
Risk Class EM-6 (DGZfP):
2
Minimum Working Distance:
10 cm
Irradiated Area in 38cm Distance:
600 x 400 mm
Visible Output of the emitted Spectrum:
No Emission > 400nm
FWHM of the UV-Spectrum:
≤ 15 nm
Visible Reflections:
none
UV Intensity Levels:
1
Radiation Drop at the Border:
soft
Number of UV-LEDs:
33
Life Time T70:
> 10.000 h
Life Time T50:
> 15.000 h
Stability of UV-Intensity:  ?maximum lost of UV-Intensity, during normal operation, only due to the self-heating of the lamp-system
> 95 %
 

Electrical Data

Provision of Electricity:
Mains-operated (AC)
Protection Type:
IP 20
Protection Class:
I (Grounded)
 

Technical Data

Dimension:
542 x 309 x 145 mm (21,4 x 12,1 x 5,7 inch)
Weight:
16
Cooling:
Fan Cooled
 

Controlling

Fan Controlling and Monitoring:  ?the Fan Output is automaticly controlled
yes
Monitoring of the Temperatur:  ?the Lamp will be cut off automaticly when the Temperature is too high
yes
Automaticly Cutout in Fail of Fault:  ?the Lamp will be automaticly cutout in Fail of Fault
yes
optical and acoustical Alarm in Fail of Fault  ?in Fail of Fault there is an acoustic signal and the UV-Switcher will blinking
yes
Operating Hours Counter:
yes
 

You may also be interested in the following product(s)

UVED-S610-F1 Stationary Medium-Size UV-A-LED-Flood-Lamp with medium irradiated area and System-Monitoring for Maximum Process-Security over 15,000 h useful time

UVED-S610-F1 Stationary Medium-Size UV-A-LED-Flood-Lamp with medium irradiated area and System-Monitoring for Maximum Process-Security over 15,000 h useful time

• medium irradiated area
• fan-control and temperature-monitoring
• overheat-protection to protect the LEDs
• adjustable UV-intensity (in factory)
• integrated operation-hour-meter
• designed for 24/7 operation
• maximum reliability
• high investement protection
 
UVED-S608S stationary UV-LED-Panel-Light for Standard-Applications relating to Surface Crack Testing in Non-Destructive Testing (NDT) with 15 cm Minimum Working Distance

UVED-S608S stationary UV-LED-Panel-Light for Standard-Applications relating to Surface Crack Testing in Non-Destructive Testing (NDT) with 15 cm Minimum Working Distance

• examination area: 550 x 350 m (in 38 cm distance)
• instant ON/OFF
• uniform irradiation
• low power consumption
• optional special filter for maximum contrast available
• 15 cm minimum working distance
 
UVED-S608SW stationary UV-Floodlight for Standard Applications and Medium Sized Inspection Area with Dimmable White-Light

UVED-S608SW stationary UV-Floodlight for Standard Applications and Medium Sized Inspection Area with Dimmable White-Light

• examination area: 550 x 350 m (in 38 cm distance)
• instant ON/OFF
• uniform irradiation
• low power consumption
• optional special filter for maximum contrast available
• 15 cm minimum working distance
• shiftable white-light
 
UVED-S508-FL Stationary Standard-Size UV-A-LED-Flooder with NO visible output of the emitted Spectrum

UVED-S508-FL Stationary Standard-Size UV-A-LED-Flooder with NO visible output of the emitted Spectrum

• irradiated area: 500x380mm
• fan-control and temperature-monitoring
• overheat-protection to protect the LEDs
• adjustable UV-intensity (in factory)
• integrated operation-hour-meter
• designed for 24/7 operation
• maximum reliability
• high investement protection